Cabling the LX Series
64
451-0308
NOTE: In order to expand the functionality of the serial interface, the LX
Series modular cabling allows you to connect different signals to
pin 7 of the LX Series. (This pin is an input to the LX Series.) When
a DCE device is connected to an LX Series serial port, the device's
DCD output is connected to pin 7. In this case, the signal at pin 7 is
referred to as DCD. DCD is used here for session control only, not
for flow control.
When a DTE device is connected to an LX Series serial port, the
device's DTR output is connected to pin 7 of the LX Series. In this
case, the signal at pin 7 is referred to as DSR. (This cabling scheme
also provides DECconnect compatibility, since DECconnect does
not support the DCD signal.)
MRV Communications 8-Wire Cabling
This cabling scheme provides XMT, RCV, DCD/DSR, DTR, RTS, CTS, and
two signal ground wires. This cabling is provided through RJ-45
connectors. Using this cabling scheme you can concurrently use modem
control and RTS/CTS hardware flow control, since there are four control
signals. This scheme is useful with relatively high speed devices, complex
modem control applications.
In Figure 25, one signal is referred to as CTS. The CTS signal designation
refers to the signal observed at pin 1 of each serial port. Pin 1 is
multiplexed to these signals.
This scheme is useful with the following applications:
Terminal emulation and file transfer applications, such as Kermit,
Xmodem, Microphone, etc.
Applications such as PPP using low speed modems.
Applications such as PPP using high speed modems.
Applications using CCITT V.42-compliant modems, or other devices
operating at high port speeds.