MRV Communications EM316SW-XY Guia do Utilizador

Consulte online ou descarregue Guia do Utilizador para Comutadores de rede MRV Communications EM316SW-XY. MRV Communications EM316SW-XY User guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - December 12, 2008

EM316SW-XY Fast Ethernet Multi-Function Media Converters User Guide PN 1288003-001 Revision D2 December 12, 2008

Página 2 - Table of Contents

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 2 2.1.1 Loopback Loopback tests and verifies the link integrity. It is available on the

Página 3

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 3 2.1.2 Link Integrity Notification (LIN) LIN is not available in switch mode. A single D

Página 4 - Table of Figures

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 4 2.2 Modes of Operation The EM316SW-XY supports four different operational modes. 1.

Página 5 - 1 Preliminary Considerations

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 5 2.2.1 Dual Repeater (Fiber and Copper) MODE1 ON MODE0 ON Figure 2 -- Dual Repeater

Página 6

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 6 2.2.2 Dual Converter MODE1 ON MODE0 OFF Figure 3 -- Dual Converter Mode In Dual

Página 7 - 1.7 Electrical Safety

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 7 2.2.3 Redundant Link MODE1 OFF MODE0 ON Figure 4 -- Redundant Link Mode In Redunda

Página 8 - 1.8 Laser Safety

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 8 2.2.4 Mixed-Media Switch (4-Port) MODE1 OFF MODE0 OFF Figure 5 -- Switching Mode

Página 9 - 2 Module Introduction

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 9 3 Preparation and Installation 3.1 Unpacking the Fiber Driver Module Step 1. Open the

Página 10 - 2.1.1 Loopback

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 10 3.2 Front Panel Description Figure 7 -- EM316SW-XY front panel The EM316SW-XY modu

Página 11 - 2.1.4 Redundancy

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 11 3.2.4 LED Display Information Figure 8 -- EM316SW-XY front panel LED Color Solid o

Página 12 - 2.2 Modes of Operation

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 i Table of Contents 1 Preliminary Considerations...

Página 13 - PN 1288003-001, Rev D2

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 12 3.3 DIP Switches The default configuration is established by the firmware preloaded onto

Página 14 - 2.2.2 Dual Converter

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 13 3.3.2 Switch Functions and Default Settings The switch block number is not sequential on

Página 15 - 2.2.3 Redundant Link

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 14 Switch Block 2* (SW2) DIP Switch DIP Switch Name Setting Bold = Defaults Description O

Página 16

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 15 Switch Block 3* (SW3) DIP Switch DIP Switch Name Setting Description ON (up) P2 Fa

Página 17

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 16 Module Installation Fiber Driver modules are hot-swappable and may be inserted into or

Página 18 - 3.2 Front Panel Description

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 17 Step 2. Install the module inside a Fiber Driver chassis by aligning the edge of the car

Página 19

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 18 Cleaning Fibers Fiber optic components and cables are very sensitive to dirt, dust, and

Página 20 - 3.3 DIP Switches

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 19 3.3.3 Working with SFPs The pluggable optics modules used in the EM316xx products are ex

Página 21 - Port Grouping

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 20 3.3.3.2 Mylar Tab SFP Modules The Mylar tab or nail latch on the module has a tab that y

Página 22

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 21 3.3.3.3 Actuator/Button SFP Modules The actuator/button SFP module has a button that you

Página 23

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 ii4.3.3.6 “show groups”...

Página 24 - Module Installation

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 22 3.3.3.5 Bale Clasp SFP Module The bale clasp SFP module has a bale clasp that you use to

Página 25

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 23 4 Module Management Most Fiber Driver modules, including the EM316SW-XY, may be manage

Página 26 - Cleaning Procedure

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 24 4.1 Serial Console Interface After the network management (NM) module is installed, po

Página 27 - 3.3.3 Working with SFPs

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 25 4.3 EM316LNXNM-OT Command Line Interface (CLI) The EM316LNXNM-OT provides command line

Página 28

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 26 4.3.1 EM316LNXNM-OT Boot and CLI Login The box below shows the NM boot and login to the

Página 29

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 27 4.3.2 CLI Navigation The CLI uses five operational contexts: login, configuration, cha

Página 30

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 28 4.3.3 Login Context Commands and Examples The login context refers to the only CLI st

Página 31 - 4 Module Management

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 29 4.3.3.2 “show chassis” The following box displays the configuration of the chassis.

Página 32 - 4.1 Serial Console Interface

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 30 4.3.3.4 “show version” The show version command displays revision levels for the ma

Página 33

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 31 4.3.3.6 “show groups” Management access is controlled through group and user permiss

Página 34

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 iii Table of Figures Figure 1 -- Loopback on FO1 while FO2 is in normal operation.

Página 35 - 4.3.2 CLI Navigation

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 32 4.3.3.8 “show running-config” The show running-config command displays the currentl

Página 36

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 33 4.3.3.9 “show startup-config” The show startup-config command displays the contents o

Página 37

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 34 4.3.3.10 Displaying and Saving System Parameters Use the write terminal command to di

Página 38

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 35 4.3.4 Configuration Context Enter "configuration" context, as shown below, t

Página 39

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 36 4.3.4.2 Configuring System Parameters Once the mode is changed, the prompt also chang

Página 40

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 37 4.3.5 Chassis Context Command examples in this section are applied in the chassis-level

Página 41

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 38 4.3.5.2 Other Commands The commands available at the chassis level are consistent in F

Página 42

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 39 4.3.6 Slot Context Commands and Examples The slot-level command context interacts wi

Página 43 - 4.3.4 Configuration Context

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 40 4.3.6.1 “?” The “?” is a special help character in the EM316LNXNM-OT command line. In pr

Página 44

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 41 4.3.6.2 “list” The list command displays all the full command options (including appli

Página 45 - 4.3.5 Chassis Context

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 iv 1 Preliminary Considerations 1.1 Trademarks and Copyright All trademarks are the proper

Página 46

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 42 4.3.6.3 “show” The “show” command displays management and system information related to

Página 47

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 43 Display Digital Diagnostic statistics for the SFP ports with the command shown below.

Página 48

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 44 Each module may be given a descriptive name with the command below. The show command fol

Página 49

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 45 4.3.7 Port Context Commands and Examples Command examples in this section are applied

Página 50

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 46 The box below shows the output of the “?” typed alone on the command line in the port-l

Página 51

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 47 The box below is specific to the SFP ports (P2 and P3) of the EM316SW-XY modules in NON

Página 52

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 48 The box below is specific to the SFP ports (P2 and P3) of the EM316SW-XY modules in RE

Página 53

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 49 4.3.7.2 “list” The list command displays all the full command options (including appl

Página 54

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 50 The box below illustrates the show command with no arguments in the port context of an

Página 55

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 51 4.3.7.4 “description” As with a module at the slot level, a descriptive name may be

Página 56

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 v 1.5 MRV Regulatory Compliance Contact your sales representative for more regulatory compl

Página 57

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 52 4.3.7.5 “show defaults” Default settings are listed in the show defaults command out

Página 58

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 53 4.3.7.6 “show config” The show config command displays the active environment settings

Página 59

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 54 4.3.7.8 “lin” The lin commands enable and disable the Lin Integrity Notification funct

Página 60

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 55 4.3.8 RJ-45 Port Commands The commands in this section are specific to the RJ-45 Ethern

Página 61

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 56 4.3.8.3 “mdi-pinout” This command sets the mdi/mdix pinout for the target port. 4.

Página 62

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 57 4.3.9 SFP Port Commands The following commands are specific to the SFP ports on the EM31

Página 63 - 4.3.8 RJ-45 Port Commands

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 58 4.3.9.3 “select-link” In Redundant Link mode, the “select link” command attempts to a

Página 64

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 59 4.4 Configuration Examples Each operational mode is represented below with the “show”

Página 65 - 4.3.9 SFP Port Commands

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 60 fiberdriver# show 1.3.1 Port: 1.3.1 Name: RJ-45 at 1.3.1 Protocol: Ethernet

Página 66

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 61 4.4.2 Converter Mode MODE1 ON MODE0 OFF In Converter mode, ports P1 and P2 are p

Página 67 - 4.4 Configuration Examples

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 vi 1.6 General Safety WARNING: Two people must lift large cabinet chassis. Lift with your

Página 68

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 62 fiberdriver# show 1.3.1 Port: 1.3.1 Name: RJ-45 at 1.3.1 Protocol: Ether

Página 69 - 4.4.2 Converter Mode

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 63 fiberdriver# show 1.3.4 Port: 1.3.4 Name: RJ-45 at 1.3.4 Protocol: Ethern

Página 70

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 64 4.4.3 Redundant Mode MODE1 OFF MODE0 ON iberdriver# show 1.3 Slot: 1

Página 71

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 65 4.4.4 Switching Mode MODE1 OFF MODE0 OFF P1 and P4 are copper RJ-45 Ethernet ports

Página 72 - 4.4.3 Redundant Mode

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 66 Ports P2 & P3 (SFP) Port P4 (Copper) fiberdriver# show 1.3.2 Port: 1.3

Página 73 - 4.4.4 Switching Mode

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 67 5 Appendix 5.1 Technical Specifications Operating Temperature Range: EM316SW-XY Æ

Página 74

20415 Nordhoff Street Chatsworth, CA 91311 Tel: 818-773-0900 Fax: 818-773-0906 http://www.mrv.com

Página 75 - 5 Appendix

Fiber Driver® EM316SW-XY 1.8 Laser Safety WARNING: Do not open laser devices for service. Removing the cover may cause exposure to harmful

Página 76

Fiber Driver® EM316SW-XY PN 1288003-001, Rev D2 1 2 Module Introduction The Fiber Driver EM316SW-XY is a highly configurable multi-functi

Comentários a estes Manuais

Sem comentários